With output voltage capabilities including 120V/240V (split phase), 208V (2/3 phase), and 230V (single phase), the N3H-X5-US inverter is equipped with a user-friendly interface for effortless monitoring and control. This empowers users to effectively manage their power systems, providing versatile and dependable power for families.
Flexible configuration, plug and play set-up built-in fuse protection.
Includes low-voltage batteries.
Engineered to last with maximum flexibility Suitable for outdoor installation.
Monitor your system remotely via smartphone app or web portal.
Model | N3H-X12-US | ||||
PV input | |||||
Max.DC input power (kW) | 18 | ||||
No. of MPPT trackers | 4 | ||||
MPPT voltage range (V) | 120~430 | ||||
MAX. DC input voltage (V) | 500 | ||||
MAX. input current per MPPT (A) | 16/16/16/16 | ||||
MAX. short current per MPPT (A) | 22 | ||||
Battery input | |||||
Nominal voltage (V) | 48 | ||||
MAX.charging/discharging current (A) | 250/260 | ||||
Battery voltage range (V) | 40-58 | ||||
Battery type | Lithium /Lead-acid | ||||
Charging controller | 3-Stage with equalization | ||||
AC output(on-grid) | |||||
Nominal output power output to grid (kVA) | 12 | ||||
MAX. apparent power output to grid (kVA) | 13.2 | ||||
Nominal AC voltage(L-N/L1-L2) (V) | (110~120)/(220~240)split phase, 240V single phase | ||||
Nominal AC frequency(Hz) | 50/60 | ||||
Nominal AC current (A) | 50 | ||||
Max. AC current (A) | 55 | ||||
Max. grid passthrough current (A) | 200 | ||||
Output power factor | 0.8leading~0.8lagging | ||||
Output THDi | <3% | ||||
AC output(back-up) | |||||
Nominal. apparent power (kVA) | 12 | ||||
Max. apparent power(no PV) (kVA) | 12 | ||||
Max. apparent power(wtih PV) (kVA) | 13.2 | ||||
Nominal output voltage(V) | 120/240 | ||||
Nominal output frequency (Hz) | 60 | ||||
Output THDu | <2% | ||||
Protection | |||||
Arc fault protection | Yes | ||||
Island protection | Yes | ||||
Insulation resistor detection | Yes | ||||
Residual current monitoring unit | Yes | ||||
Output over current protection | Yes | ||||
Back-up output short protection | Yes | ||||
Output over voltage protection | Yes | ||||
Output under voltage protection | Yes | ||||
General data | |||||
Mppt efficency | 99.9% | ||||
Europe efficiency(PV) | 96.2% | ||||
Max. PV to grid efficiency(PV) | 96.5% | ||||
Max. battery to load efficiency | 94.6% | ||||
Max. PV to battery charing efficiency | 95.8% | ||||
Max. grid to battery charing efficiency | 94.5% | ||||
Operating temperature range (℃) | -25~+60 | ||||
Relative humidity | 0-95% | ||||
Operating altitude | 0~4,000m(Derating above 2,000m altitude) | ||||
Ingress protection | IP65/NEMA 3R | ||||
Weight (kg) | 53 | ||||
Weight (with breaker) (kg) | 56 | ||||
Dimensions W*H*D (mm) | 495 x 900 x 260 | ||||
Cooling | FAN cooling | ||||
Noise emission (dB) | 38 | ||||
Display | Touch panel | ||||
Communication with BMS/Meter/EMS | RS485, CAN | ||||
Supported communication interface | RS485, 4G (optional), Wi-Fi | ||||
Self-consumption | <25W | ||||
Safety | UL1741, UL1741SA&SB all options, UL1699B, CSA -C22.2 NO.107.1-01,RSD(NEC690.5,11,12), | ||||
EMC | FCC part 15 class B | ||||
Grid connection standards | IEEE 1547, IEEE 2030.5, HECO Rule 14H, CA Rule 21 Phase I,II,III,CEC, CSIP,SRD2.0,SGIP,OGPe,NOM,California Prob65 |
||||
Other data | |||||
Backup conduit | 3″ | ||||
Grid conduit | 3″ | ||||
AC solar conduit | 2″ | ||||
PV input conduit | 2″ | ||||
Bat input conduit | 2″ | ||||
PV switch | Integrated |
Object | Description |
01 | BAT inpu/BAT output |
02 | WIFI |
03 | Communication Pot |
04 | CTL 2 |
05 | CTL 1 |
06 | Load 1 |
07 | Ground |
08 | PV input |
09 | PV output |
10 | Generator |
11 | Grid |
12 | Load 2 |
Drop your email for product inquiries or price lists - we'll respond within 24 hours. Thanks!