N1F-A6.2P is compatible with lifepo4 batteries through RS485 and can run up to 12 single-phase/three-phase/split-phase functions in parallel, optimizing battery performance and extending life cycle, improving system capacity and scalability,
An off-grid machine is an independent power generation system that uses solar panels to convert solar energy into direct current and then converts the direct current into alternating current through an inverter. It does not need to be connected to the main grid and can operate independently.
N1F—A6.2P Split Phase off Grid Inverter is specifically designed for seamless integration with 110V power grids, and is engineered for outdoor installation, ensuring durability and longevity. Trust in its reliability, even in harsh environmental conditions.
MODEL |
N1F-A6.2P |
Capacity | 6.2KVA/6.2KW |
Parallel Capability | YES,12 Units |
INPUT |
|
Nominal Voltage | 230VAC |
Acceptable Voltage Range | 170-280VAC(For personal Computer); 90-280vac(For Home Appliances) |
Frequency | 50/60 Hz(Auto sensing) |
OUTPUT |
|
Nominal Voltage | 220/230VAC±5% |
Surge Power | 12400VA |
Frequency | 50/60Hz |
Waveform | Pure Sine wave |
Transfer Time | 10ms(For personal Computer);20ms(For Home Appliances) |
Peak Efficiency | 94% |
Overload Protection | 5s@>= 150%load;10s@110%~ 150%load |
Crest Factor | 3:1 |
Admissible Power Factor | 0.6~ 1(inductive or capacitive) |
BATTERY |
|
Battery Voltage | 48VDC |
Floating Charge Voltage | 54VDC |
OverCharge Protection | 63VDC |
Charging Method | CC/CV |
Solar Charger &AC Charger |
|
Solar Charger Type | MPPT |
Max.PV Array Power | 6500W |
Max.PV Array Open Circuit Voltage | 500VDC |
PV Array MPPT Voltage Range | 60VDC~450VDC |
Max.Solar Input Current | 27A |
Max.Solar Charge Current | 120A |
Max.AC Charge Current | 80A |
Max.Charge Current | 120A |
PHYSICAL |
|
Dimensions , DxWxH | 450x300x130mm |
Package Dimensions , DxWxH | 540x390x210mm |
Net Weight | 9.6KG |
Communication Interface | RS232/RS485/Dry-contact |
ENVIRONMENT |
|
Operating Temperature Range | - 10℃~55℃ |
Storage Temperature | - 15℃~60℃ |
Humidity | 5%to 95%Relative Humidity(Non-condensing) |
1 | LCD display |
2 | Status indicator |
3 | Charging indicator |
4 | Fault indicator |
5 | Function buttons |
6 | Power on/off switch |
7 | AC input |
8 | AC output |
9 | PV input |
10 | Battery input |
11 | RS232 communication port |
12 | Parallel communication port (only for parallel model) |
13 | RS485 communication port |
14 | Grounding |
15 | WiFi module avoidance hole (Onlyuse WiFi module models to remove) |
16 | RS485 communication line outlet |
17 | Battery positive outet hole |
18 | Battery negative outlet hole |